Description Wire Colors Pin
Heater power supply ground Blue, Black, Red, Yellow 7 and 8
COM2 RS-485, B Brown 3
COM2 RS-485, A Red/Blue 14
Communications ground Violet 10
Enclosure ground Shield Shield
The wiring depends on the heating option selected for the sensor:
• One power supply produces enough power for WMT700 without heating (0 W) or with
transducer heating only (30 W).
• WMT700 with transducer and arms heating (150 W) requires an additional power
supply.
The heating power supply wires are internally connected to each other. If
the connection cable has two positive heating supply wires, both must be connected to
each other. Leaving one terminal unconnected or connecting it to the ground may cause
a malfunction or a short-circuit in the power supply.
CAUTION!
6.4 Installing WA15
WA15 consists of anemometer WAA151, wind vane WAV151, and serial wind transmitter
WAC155.
For the most reliable measurements:
• Avoid trees or other objects nearby which could disturb wind
flow.
• Install the sensor to the height that best represents the prevailing wind conditions on
site.
AWS310/AWS310-SITE Installation Manual M211584EN-F