To prevent equipment damage, install an air terminal so that the tip is as
high above the instruments and sensors as possible.
CAUTION!
To prevent corrosion and oxidation, use copper paste or equivalent on screws and
connector threads.
More Information
Connecting WXT520 Cable (page 71)
Aligning WXT520 (page 72)
Configuring Wind Direction Oset (page 73)
6.5.1
 Connecting WXT520 Cable
Make sure that you prepare or connect only de-energized wires.WARNING!
Do not perform installation or maintenance procedures when there is a
risk of thunderstorm or lightning activity in the area.
WARNING!
A long cable between units (sensors, transmitters, power supplies, and
displays) can cause a lethal lightning-induced current surge. Always ground the
enclosure to a suitable grounded location with a short, low-resistance cable.
WARNING!
Chapter 6 – Wind Sensor or Weather Transmitter Installation
71