16.6.4.3 Edit Keypads
To edit keypads:
1. Scroll to KEYPADS > EDIT.
2. Press SELECT.
3. Scroll to the device to be edited and press SELECT.
The configuration settings for a standard keypad and comfort keypad are described in the
sections below.
4. Press BACK to exit the menu.
LCD Keypad Settings
Configure the following settings for the keypad.
Setting Description
Description Enter a unique description to identify the keypad.
Function Keys (in idle state)
Panic Select Enable, Disable or Enabled Silent. If enabled, panic alarm is activated by pressing the 2
soft keys together.
Verification If you assign a verification zone to the keypad, when a panic alarm is triggered by pressing 2 soft
keys together or by entering a duress code, audio and video events are activated.
Visual Indications
Backlight Select when keypad backlight is on. Options are: On after key is pressed; Always on; Always off.
Indicators Enable or disable the LED’s on the keypad.
Setting
state
Select if setting state should be indicated in idle mode.
Audible Indications
Buzzer Enable or disable the buzzer on the keypad.
Partset
Buzzer
Enable or disable buzzer during exit time on Partset.
Keypress Select if the speaker volume for the key presses should be activated.
Deactivation
Calendar Select if the keypad should be limited by calendar. See Calendars on page284.
Mapping
gate
Select if keypad should be limited by a mapping gate.
Keyswitch Select if keypad should be limited by a keyswitch.
PACE
Entry
Tick this box to disable the keys on the keypad during the entry time when a PACE is configured
on the keypad.
Areas
Location Select the secured area where the keypad is located.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Engineer programming via the keypad
© Vanderbilt 2018 126 A6V10276959-d