Unrestricted Grade
A Security Grade setting of Unrestricted does not apply to any regionally approved security
restrictions of the installation. Instead, the Unrestricted setting enables an engineer to customize the
installation by changing security policy options and configuring additional options which do not comply
with the selected regional security compliance.
Unrestricted configuration options are denoted in this document by the following symbol:
See System Options on page252 for details of configuring system policies.
17.10.3.5 Clock
This page allows you to program the date and time on the panel. The controller contains a Real-Time
Clock (RTC) that is battery backed to preserve the time and date information in the event of power
failure.
1. Select Configuration > System > Clock.
The following page will be displayed.
2. Select the Time and Date from the drop down menus.
3. Configure the following fields:
Automatic Daylight Saving
Time
If selected, the system will automatically switch to summer
time
Synchronize time with
Mains
If selected, the RTC synchronizes itself with the sine wave in
the power line
The selected time and date will be displayed on the keypad, the web interface and the event log.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2018 268 A6V10276959-d
11.2018

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC42 Series and is the answer not in the manual?

Vanderbilt SPC42 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC42 Series
CategoryPower Supply
LanguageEnglish

Related product manuals