All Okay
All Okay
Required
If selected, user must confirm ‘All okay’ input or silent alarm is generated. See Editing a zone on
page270 for details on configuring an ‘All Okay’ zone input.
All Okay
Time
Time (in seconds) in which ‘All okay’ must be confirmed before alarm is raised. (Range: 1–999
seconds)
All Okay
Event
Select the event type to be sent when the ‘All okay’ timer expires. Options are Panic (Silent), Panic
and Duress.
RF Output
RF Output Time Enter the number of seconds that the RF Output will remain on for.
0 seconds will toggle the output on and off.
Fire Exit Route
Fire exit
route
Select the doors which will open when fire occurs in this area. This option does not display in
domestic mode.
Area Triggers
The Triggers section is only displayed if triggers have been defined previously. (See Triggers on page288.)
Click the Edit button to add, edit or delete trigger conditions for the area.
The following page is displayed:
Configure the trigger for the area using the following parameters:
Trigger Select a trigger from the drop down list.
Edge The trigger can activate from either the positive or negative edge of the activation signal.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2018 277 A6V10276959-d
11.2018

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC42 Series and is the answer not in the manual?

Vanderbilt SPC42 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC42 Series
CategoryPower Supply
LanguageEnglish

Related product manuals