Dial Up Internet Configuration
Dial Up
Internet
Enable
Select this option to enable the modem to gain internet access through a dial-up connection
Phone
Number
Enter the phone number for the dial-up connection.
Username Enter the dial-up connection Username.
Password Enter the dial-up connection Password.
Click the Test SMS button to send a short text message for the purposes of testing the system.
The SMS test is provided only for the purpose of ensuring the SMS feature is operating correctly. A
short text message using alphabetic characters (A-Z) should be used to test this feature.
PSTN modem
1. Select Communications > Communications > Modems.
2. Click Configure.
3. Configure the fields as described in the table below.
PSTN Modem settings
Country Select the country that the SPC is installed in.
Incoming
Calls
The modem can be programmed to answer calls based on the following conditions:
l Don’t answer incoming calls Modem never answers calls.
l Answer after ‘x’ rings Select the number of rings (1 to 8) after which the modem answers the
incoming call.
l Answer when after one ring phone is hung up, then immediately dialled again If the
calling party calls the modem, hangs up after 1 ring burst only, and then immediately re-calls the
modem. The SPC system knows to automatically answer the call in this condition.
l Only answer when engineer access is granted The modem only answers the call while
engineer access is granted to the system.
Prefix Enter the number required to access a line (for example, if connected to a PBX).
Line
Monitoring
Enable this feature to monitor the voltage of the line connected to the modem.
Note: EN 50131-9 Confirmation configuration – In order for EN50131-9 Confirmation to operate
correctly, line monitoring must be enabled. (See Options on page252.)
Monitoring
Timer
Select the period (in seconds) for which the line voltage must be seen as being incorrect before the
line is deemed by the SPC to be faulty.
Modem
Fault Time
Time delay for a system alert (0–9999 seconds). Default 60 seconds.
SPC4xxx/5xxx/6xxx – Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2018 301 A6V10276959-d
11.2018

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC42 Series and is the answer not in the manual?

Vanderbilt SPC42 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC42 Series
CategoryPower Supply
LanguageEnglish

Related product manuals