Generate
FTC
Select whether the system generates a FTC on an ATS event timeout.
Re-
queue
Events
Select this to re-queue events after an ATS Timeout.
Re-
queue
Event
Delay
Delay after an ATS Event Timeout before the re-queued event is attempted
again. Default: 300 seconds.
Re-
queue
Event
Duration
Amount of time that the event will be re-queued before the event is deleted.
Default: 86400 seconds.
10. Click the Edit Installation Details button to complete the settings to identify the panel to the RCT
operator. See Edit Installation Details on page316.
11. Click Save and Back to return to the ATS Configuration page. The new ATS displays in the
Configured ATS table.
12. For multiple ATPs, you can use the up and down arrows in the Event Sequence Table to reorder
the ATP sequence.
NOTICE: The ATS Registration ID is automatically generated for an ATS. It uniquely identifies the
panel to the RCT. If you do not know the SPT Account Code, you can commission the panel using
this ATS Registration ID. The CMS operator must also enter this ATS Registration ID at the RCT (for
example, SPC Com XT). See the SPC Com XT Installation & Configuration Manual.
See also
ATS Category Timings on page397
Add ATP to FlexC RCT
Add ATP to FlexC RCT allows you to configure an ATP between the SPC panel and the RCT (for
example, SPC Com XT). You can configure up to 10 ATPs for each ATS.
1. Click the button Add ATP to FlexC RCT.