3. Enter a Name to identify the command profile.
4. Select an Authentication Mode (Command User or Panel User, Command User Only, or Any
Panel User) from the dropdown menu.
NOTICE: The default Command User Name provides an out of the box user that
quickly and easily enables control of the panel from SPC Com XT. It enables a
broad range of commands. For example, the default command user can set all
areas or control all zones. For tighter control, for example to only allow setting of
certain areas, you can set up a customised command profile with a defined set of
rights. You cannot delete the Default Command Profile, the Default Portal
Command Profile or a command profile that is assigned to an ATS.
5. Enter the name of the command profile user in the Command User Name field. This must match
the Authentication User Name field in SPC Com XT.
6. Enter the password of the command profile user in the Command Password field. This must
match the authentication User PIN or Password field in SPC Com XT.
7. Select the Live Streaming Mode (Disabled, Only after alarm event, Always available, System is
fullset) to determine the streaming privacy options. Always Available generates the highest
volume of data.
8. Under Command Filter, select the commands to enable. For a full list of commands, see FlexC
Commands on page394.
9. Select the commands to log.
10. Click Save.
11. Click Back to view the command profile in the Command Profiles table.
12. To change a command profile, click the Edit button (pencil icon) next to a command profile.
17.11.3 Reporting
This section covers:
l Alarm Reporting Centres (ARCs) on the facing page
l EDP Setup on page327
l CEI-ABI Protocol Settings on page335