Move Floating Point Data
S : the source device to be transferred
D : the destination device
To copy the designated value from to .
The content value of the BIN oating point format in D1, D0 will be copied to D11, D10 when the X0 = “ON”.
The instruction is disabled and D11, D10 remain invariable when the X0 = “OFF”.
This instruction is a 32-bit instruction. Therefore, be sure to input DEMOV or DEMOVP in the program.
The format for storing a oating point number will occupy two Registers in the PLC system. Please refer to the
section 2-13 “Numerical System” for the reference of the oating point number.