EasyManua.ls Logo

Wacker Neuson WL34 - Battery Maintenance

Wacker Neuson WL34
348 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-58 SHB WL34 * 2.0
1 Maintenance
Maintenance
5. Set all control levers and switches to the zero position.
6. Switch off all electric consumers and remove the starting key.
7. Open the engine cover.
8. Switch off and remove the battery master switch.
Way of proceeding:
1. Unscrew the cover plate 1 (2 screws, WS 10).
2. Unscrew the line from the negative terminal ().
3. Unscrew the line from the positive terminal (+).
4. Unscrew the battery holder.
5. Remove the battery.
Information
Install the battery in the reverse order.
Environment
Avoid environmental damage.
Dispose of old batteries in an environmentally friendly manner and
separately from other waste.
Battery maintenance
Observe the Operator’s Manual of the battery. The Operator’s Manual of
the battery is fastened on one side of the battery 1.
Always keep the terminals on the battery and connecting cables clean
and lubricate them with anti-corrosion grease.
Ensure that the cover of the positive terminal 2 is always in place and
closed.
Observe the monitoring device of the battery located in position 3.
- Green = battery charge condition OK.
- Black = charge the battery.
- White = replace the battery by a new one.
Fig. 67
+
1
Fig. 68
1
2
3

Table of Contents