E-8 SHB WL34 * 2.0
E Introduction
Technical data
Operating hydraulics
Coolant
Important information on coolants
Check the coolant level regularly. The coolant must cover the radiator fins.
Ensure that enough antifreeze is always added to the coolant, even in
summer. The antifreeze also prevents internal corrosion of the radiator
and the engine.
Coolant compound table
Machine with Perkins engine 404D-22 (35.7 kW)
Oil flow l/m (gal/min) 49 (12.9)
Operating pressure bar (psi) 210 (3046)
Machine with Perkins engine 404F-22 (35.7 kW)
Oil flow l/m (gal/min) 49 (12.9)
Operating pressure bar (psi) 210 (3046)
Machine with Deutz engine TD2011L04 (55.1 kW)
Oil flow l/m (gal/min) 52 (13.7)
Operating pressure bar (psi) 210 (3046)
Outside temperature Water Antifreeze
Up to °C (°F) % by volume % by volume
-37 (-34.6) 50 50
1. Use the 1:1 concentration for warm outside temperatures too in order to ensure protection against cor-
rosion, cavitation and deposits.
2. Do not mix the coolant with other coolants.