EasyManua.ls Logo

Wacker Neuson WL34 - Page 323

Wacker Neuson WL34
348 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SHB WL34 * 2.0 12-5
Malfunctions 12
Error code lists
3241 Exhaust-gas treatment temperature sensor 1 15 Valid data, but above the normal range Over 700 °C
- Limited engine speed and torque
- Suppression of necessary regeneration
3241 Exhaust-gas treatment temperature sensor 1 16 Valid data, but above the normal range Over 800 °C and less than 5 V
- Engine stop
- Engine emergency stop
- Suppression of necessary regeneration
3242
Exhaust-gas treatment 1 diesel particulate filter
intake temperature sensor
1 Valid data, but below the normal range Below 50 °C and below the setting
- Limited engine speed and torque
- Suppression of necessary regeneration
- Incorrect soot load estimate
3242
Exhaust-gas treatment 1 diesel particulate filter
intake temperature sensor
3 Voltage too high Below setting and over 5 V
- Limited engine speed and torque
- Suppression of necessary regeneration
- Incorrect soot load estimate
3242
Exhaust-gas treatment 1 diesel particulate filter
intake temperature sensor
4 Voltage too low Over 999 °C and below 0.05 V
- Limited engine speed and torque
- Suppression of necessary regeneration
- Incorrect soot load estimate
3242
Exhaust-gas treatment 1 diesel particulate filter
intake temperature sensor
15 Valid data, but above the normal range Over 700 °C
- Limited engine speed and torque
- Suppression of necessary regeneration
3242
Exhaust-gas treatment 1 diesel particulate filter
intake temperature sensor
16 Valid data, but above the normal range Over 800 °C and less than 5 V
- Engine stop
- Engine emergency stop
- Suppression of necessary regeneration
3251
Exhaust-gas treatment 1 diesel particulate filter
differential pressure sensor
3 Voltage too high Over 5 bar and below 4.75 V
- Limited engine speed and torque
- Incorrect soot load estimate
3251
Exhaust-gas treatment 1 diesel particulate filter
differential pressure sensor
4 Voltage too low 0 bar and over 0.25 V
- Limited engine speed and torque
- Incorrect soot load estimate
3473 Exhaust-gas treatment 7 Mechanism does not react Misfiring in burner
- Suppression of necessary regeneration
- Limited engine power
- Engine speed fluctuating
3473 Exhaust-gas treatment 11 Error during ignition Misfiring in burner
- Suppression of necessary regeneration
- Limited engine power
- Engine speed fluctuating
3484 Exhaust-gas treatment 1 ignition 0 Valid data, but above the normal range Over 12 V - Faulty glow plug
3484 Exhaust-gas treatment 1 ignition 3 Voltage too high Over 21.9 V - Faulty glow plug
3484 Exhaust-gas treatment 1 ignition 4 Voltage too low Under 5.1 V - Suppression of necessary regeneration
3556 Exhaust-gas treatment hydrocarbon dosage 6 Power consumption too high - -
3610 Diesel particulate filter 1 output pressure sensor 3 Voltage too high Over 20 bar and over 4.75 V
- Limited engine speed and torque
- Incorrect soot load estimate
3610 Diesel particulate filter 1 output pressure sensor 4 Voltage too low Below 1.4 bar and below 0.5 V
- Limited engine speed and torque
- Incorrect soot load estimate
3713
Regeneration of diesel particulate filter actively
blocked; Time-out
7 Mechanism does not react
DOC-In temperature incorrect during
regeneration
- Suppression of necessary regeneration
- Limited engine power
- Engine speed fluctuating
3713
Regeneration of diesel particulate filter actively
blocked; Time-out
31 Error Misfiring in burner
- Suppression of necessary regeneration
- Limited engine power
- Engine speed fluctuating
Error code
Error setting condition
(detection threshold)
Reaction MotorSPN (component) FMI (error type)
SPN SPN text FMI FMI text