SHB WL34 * 2.0 12-9
Malfunctions 12
Error code lists
517918 Identification error 12 Internal control unit error Ignition ON Internal reset condition fulfilled
518905 OMD load indicator <--> ECU error 9 Timeout while receiving CAN message Ignition ON Ignition off/on
518905 OMD load indicator <--> ECU error 19 Data reception with active error status Ignition ON Ignition off/on
518905 OMD load indicator <--> ECU error 24 Difference between CAN message and pin signal Ignition ON Ignition off/on
518960 Parking-brake switch S011 26 Channel “NO” not in valid range Ignition ON Ignition off/on
518960 Parking-brake switch S011 24 Difference between channels Ignition ON Ignition off/on
518970 Creep gear push button S021 3 Short circuit to battery Ignition ON Ignition off/on
518970 Creep gear push button S021 4
Actuated too long or short circuit to ground longer than 10 sec-
onds
Ignition ON Ignition off/on
518970 Creep gear push button S021 26 Value not in valid range Ignition ON Ignition off/on
518974 Differential lock key S025 3 Short circuit to battery Ignition ON Ignition off/on
518974 Differential lock key S025 4
Actuated too long or short circuit to ground longer than 60 sec-
onds. [Only while button is pressed – error resets automati-
cally]
Ignition ON Ignition off/on
518974 Differential lock key S025 26 Value not in valid range Ignition ON Ignition off/on
519015 Neutral switch S066 4 Short circuit to ground Ignition ON Ignition off/on
519015 Neutral switch S066 28 Open wiring or short circuit to Bat+ Ignition ON Ignition off/on
519015 Neutral switch S066 26 Value not in valid range Ignition ON Ignition off/on
519033 Switch VLS OFF S084 24 Logic error between redundant signals Ignition ON Ignition off/on
519050 Hydro comfort switch S101 3 Short circuit to Bat+ Ignition ON Ignition off/on
519050 Hydro comfort switch S101 26 Value not in valid range Ignition ON Ignition off/on
519053 Operator presence switch S104 24 Difference between channels Ignition ON Ignition off/on
519058 Switch electric function 1 S109 4 Short circuit to ground Ignition ON Ignition off/on
519058 Switch electric function 1 S109 26 Value not in valid range Ignition ON Ignition off/on
519058 Switch electric function 1 S109 28 Open wiring or short circuit to Bat+ Engine is running Ignition off/on
519059 Switch electric function 2 S110 4 Short circuit to ground Ignition ON Ignition off/on
519059 Switch electric function 2 S110 26 Value not in valid range Ignition ON Ignition off/on
519059 Switch electric function 2 S110 28 Open wiring or short circuit to Bat+ Engine is running Ignition off/on
519060 Road-travel lock switch S111 24 Difference between channels Ignition ON Ignition off/on
519065 Limit switch 1 S116 / limit switch 2 S142 24 Logic error between both switches Engine is running Ignition off/on
519066 Joystick push button 2 S117 3 Short circuit to Bat+ Engine is running Ignition off/on
519066 Joystick push button 2 S117 4
Actuated too long or short circuit to ground longer than 60 sec-
onds
Ignition ON Ignition off/on
519066 Joystick push button 2 S117 26 Value not in valid range Engine is running Ignition off/on
519090 VLS mode switch S141 24 Logic error between redundant signals Ignition ON Ignition off/on
519090 VLS mode switch S141 26 Channel “NC” not in valid range Ignition ON Ignition off/on
519107
Pilot control pressure switch raise/lower S162/
S163
24 Logic error between raise and lower Engine is running Ignition off/on
Error code
Fault detection during/starting with
machine condition
Reset conditionSPN (component) FMI (error type)