EasyManua.ls Logo

Wacker Neuson WL34 - Page 327

Wacker Neuson WL34
348 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SHB WL34 * 2.0 12-9
Malfunctions 12
Error code lists
517918 Identification error 12 Internal control unit error Ignition ON Internal reset condition fulfilled
518905 OMD load indicator <--> ECU error 9 Timeout while receiving CAN message Ignition ON Ignition off/on
518905 OMD load indicator <--> ECU error 19 Data reception with active error status Ignition ON Ignition off/on
518905 OMD load indicator <--> ECU error 24 Difference between CAN message and pin signal Ignition ON Ignition off/on
518960 Parking-brake switch S011 26 Channel “NO” not in valid range Ignition ON Ignition off/on
518960 Parking-brake switch S011 24 Difference between channels Ignition ON Ignition off/on
518970 Creep gear push button S021 3 Short circuit to battery Ignition ON Ignition off/on
518970 Creep gear push button S021 4
Actuated too long or short circuit to ground longer than 10 sec-
onds
Ignition ON Ignition off/on
518970 Creep gear push button S021 26 Value not in valid range Ignition ON Ignition off/on
518974 Differential lock key S025 3 Short circuit to battery Ignition ON Ignition off/on
518974 Differential lock key S025 4
Actuated too long or short circuit to ground longer than 60 sec-
onds. [Only while button is pressed – error resets automati-
cally]
Ignition ON Ignition off/on
518974 Differential lock key S025 26 Value not in valid range Ignition ON Ignition off/on
519015 Neutral switch S066 4 Short circuit to ground Ignition ON Ignition off/on
519015 Neutral switch S066 28 Open wiring or short circuit to Bat+ Ignition ON Ignition off/on
519015 Neutral switch S066 26 Value not in valid range Ignition ON Ignition off/on
519033 Switch VLS OFF S084 24 Logic error between redundant signals Ignition ON Ignition off/on
519050 Hydro comfort switch S101 3 Short circuit to Bat+ Ignition ON Ignition off/on
519050 Hydro comfort switch S101 26 Value not in valid range Ignition ON Ignition off/on
519053 Operator presence switch S104 24 Difference between channels Ignition ON Ignition off/on
519058 Switch electric function 1 S109 4 Short circuit to ground Ignition ON Ignition off/on
519058 Switch electric function 1 S109 26 Value not in valid range Ignition ON Ignition off/on
519058 Switch electric function 1 S109 28 Open wiring or short circuit to Bat+ Engine is running Ignition off/on
519059 Switch electric function 2 S110 4 Short circuit to ground Ignition ON Ignition off/on
519059 Switch electric function 2 S110 26 Value not in valid range Ignition ON Ignition off/on
519059 Switch electric function 2 S110 28 Open wiring or short circuit to Bat+ Engine is running Ignition off/on
519060 Road-travel lock switch S111 24 Difference between channels Ignition ON Ignition off/on
519065 Limit switch 1 S116 / limit switch 2 S142 24 Logic error between both switches Engine is running Ignition off/on
519066 Joystick push button 2 S117 3 Short circuit to Bat+ Engine is running Ignition off/on
519066 Joystick push button 2 S117 4
Actuated too long or short circuit to ground longer than 60 sec-
onds
Ignition ON Ignition off/on
519066 Joystick push button 2 S117 26 Value not in valid range Engine is running Ignition off/on
519090 VLS mode switch S141 24 Logic error between redundant signals Ignition ON Ignition off/on
519090 VLS mode switch S141 26 Channel “NC” not in valid range Ignition ON Ignition off/on
519107
Pilot control pressure switch raise/lower S162/
S163
24 Logic error between raise and lower Engine is running Ignition off/on
Error code
Fault detection during/starting with
machine condition
Reset conditionSPN (component) FMI (error type)
SPN SPN text FMI FMI text

Table of Contents