Malfunctions 12
Error code lists
519382 Auxiliary hydraulics valve A Y033 26 Current deviation at output Ignition ON Ignition off/on
519382 Auxiliary hydraulics valve A Y033 28 Open wiring or external short circuit to Bat+ Engine is running Ignition off/on
519383 Auxiliary hydraulics valve B Y034 3 Internal short circuit to Bat+ Ignition ON Ignition off/on
519383 Auxiliary hydraulics valve B Y034 5 Open wiring or external short circuit to Bat+ Engine is running Ignition off/on
519383 Auxiliary hydraulics valve B Y034 6 Short circuit to ground or output overload Ignition ON Ignition off/on
519383 Auxiliary hydraulics valve B Y034 12 Internal error at output driver Ignition ON Ignition off/on
519383 Auxiliary hydraulics valve B Y034 26 Current deviation at output Ignition ON Ignition off/on
519383 Auxiliary hydraulics valve B Y034 28 Open wiring or external short circuit to Bat+ Engine is running Ignition off/on
519400 Hydro comfort valve Y051 4 Short circuit to ground or thermal overload Ignition ON Ignition off/on
519400 Hydro comfort valve Y051 12 Internal error at output driver Ignition ON Ignition off/on
519400 Hydro comfort valve Y051 28 Open wiring or short circuit to Bat+ Engine is running Ignition off/on
519442
Solenoid valve (counterbalance valve activation)
Y094
3 Short circuit to Bat+ Ignition ON Ignition off/on
519442
Solenoid valve (counterbalance valve activation)
Y094
4 Short circuit to ground or thermal overload Engine is running Ignition off/on
519442
Solenoid valve (counterbalance valve activation)
Y094
12 Internal error at output driver Ignition ON Ignition off/on
519447 Solenoid valve (operating hydraulics derate) Y099 4 Short circuit to ground or thermal overload Ignition ON Ignition off/on
519447 Solenoid valve (operating hydraulics derate) Y099 12 Internal error at output driver Ignition ON Ignition off/on
519447 Solenoid valve (operating hydraulics derate) Y099 28 Open wiring or short circuit to Bat+ Ignition ON Ignition off/on
519450 Vertical Lift System valve Y102 3 Internal short circuit to Bat+ Ignition ON Ignition off/on
519450 Vertical Lift System valve Y102 5 Open wiring or external short circuit to Bat+ Engine is running Ignition off/on
519450 Vertical Lift System valve Y102 6 Short circuit to ground or output overload Ignition ON Ignition off/on
519450 Vertical Lift System valve Y102 12 Internal error at output driver Ignition ON Ignition off/on
519450 Vertical Lift System valve Y102 26 Current deviation at output Ignition ON Ignition off/on
519455 Valve (lock for long-haul travel) Y107 4 Short circuit to ground or thermal overload Ignition ON Ignition off/on
519455 Valve (lock for long-haul travel) Y107 12 Internal error at output driver Ignition ON Ignition off/on
519455 Valve (lock for long-haul travel) Y107 28 Open wiring or short circuit to Bat+ Engine is running Ignition off/on
523550 Starter 12
Starter – starter switch active too long (engine is running and
starter is active)
Engine is running Ignition off/on
523550 Starter 26 Starter – analog value not in valid range Engine start Ignition off/on
Error code
Fault detection during/starting with
machine condition
Reset conditionSPN (component) FMI (error type)
SPN SPN text FMI FMI text