1-4 SHB WL34 * 2.0
1 Maintenance
Maintenance overview
Information on batteries
Batteries give off explosive gases.
Avoid smoking, fire or open flames near batteries.
Do not place any tools on batteries. Short-circuiting the terminals
produces sparks that ignite escaping battery acid gases.
Battery acid is caustic. Avoid contact with the skin, eyes, mouth and
clothing.
Wear protective equipment.
In case of contact, immediately rinse the contaminated part of the
body with plenty of water and seek medical attention.
Always take off metal jewelry and watches before performing work on
the battery or the electrical system.
Dispose of old batteries in an environmentally friendly manner and
separately from other waste.
Information on the electrical system
Always follow the correct sequence when disconnecting the battery.
To disconnect: First the negative terminal, and then the positive
terminal.
To connect: First the positive terminal, and then the negative
terminal.
Always disconnect the battery before performing work on the electrical
system in which tools, spare parts, etc. can touch electrical compo-
nents or contacts.
Always disconnect the battery before performing welding work.
After maintenance
Once maintenance and inspection work is over, install all protections
again correctly.
Only start the engine if no more work is performed on the machine and
there are no more persons in the danger zone.
Start the machine only from the operator seat.
Once maintenance and inspection work is over, perform a functional
check of the machine.