EasyManua.ls Logo

WAREMA climatronic - Page 107

WAREMA climatronic
144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
890370_0•en•01.06.2009 We reserve the right to carry out improvements
107
Product matrix
The following overview shows the local operation modes that can be used for
each product type. The combinations marked with an x can be parameter-
ised but are not recommended or useful.
The table applies to local single operation or local group operation.
Product type
No manual operation
Dead man
Permanent mode
Radio time mode
Continuous mode
Toggling (3 steps)
Dim/adjust mode
Stair light function
Articulated arm awning
x x x
Conservatory awning
x x x
External venetian blind
x x x
Roller shutter
x x x
Pleated blind
x x x
Venetian blind
x x x
Window
x x x
Fan, fan valve
x
Fan 3 steps
x
Fan, infinitely variable (external)
x
x
Air conditioner
x x
Heater
x
Light
x
Light, dimmable (external)
x x
x
Fault alarm contact
x x x x x x x
Internal roller blind
x x x
Vertical awning
x x x
Facade awning
x x x
Drop-arm awning
x x x
Markisolette
x x x
Fan, infinitely variable, external, with valve
x x
x
Fan 6/12 V with fan valve
x
Fan, infinitely variable with fan valve x x x x x x x x
Light, dimmable x x x x x x x x
= combinable, x = not combinable/not useful
Fig. 30
Product matrix for local manual operation
NOTE The "Stop at every button press" parameter works with every product type
except for the fault sensor contact.