890370_0•en•01.06.2009
We reserve the right to carry out improvements
90
WAREMA climatronic
®
Installation Instructions
If you scroll farther down with the function wheel (), you can select whether
the wind force should also be evaluated in terms of its direction for this chan-
nel. This is useful when all products of this channel are installed with a par-
ticular orientation or in the same compass direction.
Example For example, let us say you mounted an articulated arm awning on the west-
facing terrace and the preset "Limit value WIND" for this product is 8 m/s. If
wind comes directly from the west, the awning is more at risk than if the wind
came from the east, in which case the awning would be protected against
the full force of the wind by the building. In this case, you should set the
direction-dependent limit value to 6m/s for westerly winds and keep the gen-
eral limit value of 8m/s.
Wind monitor ON/OFF
You can activate or deactivate the wind monitor by channel.
CAUTION
Before doing this, however, consider the effects this may have and observe
the safety information in these instructions.
Proceed as follows to activate or deactivate the wind monitor:
Move to the [Wind control ON/OFF] line with the function wheel and press
the function wheel.
Set or clear the checkmark in the box on the left by turning the function
wheel.
Press the function wheel to finish the setting. The first line in the display re-
minds you are performing the settings for "Channel 1".
Press the [Back] button to return to the [Safety functions] menu.
Channels