B.3 Parameter Table
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 427
Parameter List
B
S5: Short Floor Operation
S4-07
(6CDH)
UPS Power
Sets the capacity of the UPS.
Default: 0.0 kVA
Min: 0.0 kVA
Max: 100.0 kVA
265
S4-08
(6CEH)
UPS Operation Speed Limit
Selection
Determines how a speed limit should be applied to the Rescue Operation speed (S4-15) when
operating from a UPS.
0: Disabled
1: Enabled until Light Load Direction Search is complete
2: Enabled until stop
Default: 2
Min: 0
Max: 2
265
S4-12
(6D2H)
DC Bus Voltage during Rescue
Operation
Sets the DC bus voltage during Rescue Operation.
Default: 0 V
Min: 0 V
Max: 1150 V
266
S4-13
(6D3H)
Rescue Operation Power Supply
Deterioration Detection Level
Determines at which level of backup power supply deterioration a PF5 fault is triggered.
Default: 80%
Min: 10%
Max: 100%
266
S4-15
(6DAH)
<39>
Speed Reference Selection for
Rescue Operation
Selects the speed reference used for Rescue Operation.
Default: 0
Min: 0
Max: 1
266
<5> Default setting is determined by the control mode (A1-02).
<39> Available in drive software versions PRG: 7016 or later.
No. (Addr.) Name Description Setting Page
S5-01
(6ABH)
<36> When the length units are set for inches (o1-12 = 1), the setting range becomes 0.00 to 650.00 inches.
<37> When the length units are set for inches (o1-12 = 1), the setting range becomes 0.00 to 393.00 inches.
Short Floor Operation Selection 0: Disabled
1: Enabled (Short Floor)
2: Enabled (Advance Short Floor)
Default: 0
Min: 0
Max: 2
269
S5-02
(6ACH)
Nominal Speed for Short Floor
Calculation
When d1-18 (Speed Priority Selection) is set to 0 or 3, S5-02 determines the rated speed used
during Short Floor.
Default: 0.0%
Min: 0.0%
Max: 100.0%
269
S5-03
(6ADH)
Short Floor Minimum Constant
Speed Time
Sets the minimum operation time when the Advanced Short Floor function is enabled (S5-01 =
2).
Default: 0.0 s
Min: 0.0 s
Max: 2.0 s
269
S5-04
(6AEH)
Distance Calculation Acceleration
Time Gain
Set for acceleration jerk compensation in Distance Calculation.
Default: 150.0%
Min: 50.0%
Max: 200.0%
269
S5-05
(6AFH)
Distance Calculation Deceleration
Time Gain
Set for deceleration jerk compensation in Distance Calculation.
Default: 150.0%
Min: 50.0%
Max: 200.0%
269
S5-10
(6B0H)
Stopping Method Selection
0: Disabled
1: Direct Landing
2: Leveling Distance Control
Default: 0
Min: 0
Max: 2
272
S5-11
(6B1H)
Deceleration Distance
Sets the deceleration distance when Stop Distance Control is enabled.
Default: 0 mm
Min: 0 mm
Max: 32767 mm
<36>
272
S5-12
(6B2H)
Stop Distance
Sets the stopping distance when Stop Distance Control is enabled.
Default: 0 mm
Min: 0 mm
Max: 10000 mm
<37>
272
S5-13
(6D6H)
Direct Landing Minimum Speed
Level
Sets the speed level for the start of Direct Landing.
Direct Landing is essentially disabled if the starting speed for Direct Landing is less than the
maximum output speed multiplied by this parameter (E1-04 × S5-13).
Default: 20%
Min: 0%
Max: 100%
272
No. (Addr.) Name Description Setting Page
All Modes
common_
TMonly
All Modes
common_
TMonly
common_
TMonly
All Modes
common_
TMonly
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
CLV
CLV/PM
V/f OLV
common_
TMonly
CLV
CLV/PM
V/f OLV
common_
TMonly
CLV
CLV/PM
V/f OLV
common_
TMonly
CLV
CLV/PM
V/f OLV
common_
TMonly