14.1 List of Parameters
14.1.2 List of Parameters
14-22
Pn50A
2
Input Signal Selections
1
0000 hex to
FFF2 hex
2100
hex
All
After
restart
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
Input Signal Allocation Mode Reference
0
Use the sequence input signal terminals with the default alloca-
tions.
page 6-5
1 Change the sequence input signal allocations.
2 Reserved setting (Do not use.)
n.X
/S-ON (Servo ON) Signal Allocation Reference
0 Active when CN1-40 input signal is ON (closed).
page 5-17
1 Active when CN1-41 input signal is ON (closed).
2 Active when CN1-42 input signal is ON (closed).
3 Active when CN1-43 input signal is ON (closed).
4 Active when CN1-44 input signal is ON (closed).
5 Active when CN1-45 input signal is ON (closed).
6 Active when CN1-46 input signal is ON (closed).
7 The signal is always active.
8 The signal is always inactive.
9 Active when CN1-40 input signal is OFF (open).
A Active when CN1-41 input signal is OFF (open).
B Active when CN1-42 input signal is OFF (open).
C Active when CN1-43 input signal is OFF (open).
D Active when CN1-44 input signal is OFF (open).
E Active when CN1-45 input signal is OFF (open).
F Active when CN1-46 input signal is OFF (open).
n.X
/P-CON (Proportional Control) Signal Allocation Reference
0 to F
The allocations are the same as the /S-ON (Servo ON) signal allo-
cations.
page 8-74
n.X
P-OT (Forward Drive Prohibit) Signal Allocation Reference
0 Enable forward drive when CN1-40 input signal is ON (closed).
page 5-31
1 Enable forward drive when CN1-41 input signal is ON (closed).
2 Enable forward drive when CN1-42 input signal is ON (closed).
3 Enable forward drive when CN1-43 input signal is ON (closed).
4 Enable forward drive when CN1-44 input signal is ON (closed).
5 Enable forward drive when CN1-45 input signal is ON (closed).
6 Enable forward drive when CN1-46 input signal is ON (closed).
7 Set the signal to always prohibit forward drive.
8 Set the signal to always enable forward drive.
9 Enable forward drive when CN1-40 input signal is OFF (open).
A Enable forward drive when CN1-41 input signal is OFF (open).
B Enable forward drive when CN1-42 input signal is OFF (open).
C Enable forward drive when CN1-43 input signal is OFF (open).
D Enable forward drive when CN1-44 input signal is OFF (open).
E Enable forward drive when CN1-45 input signal is OFF (open).
F Enable forward drive when CN1-46 input signal is OFF (open).