No.
n.X
N-OT (Reverse Drive Prohibit) Signal Allocation Reference
0 Enable reverse drive when CN1-40 input signal is ON (closed).
page 5-31
1 Enable reverse drive when CN1-41 input signal is ON (closed).
2 Enable reverse drive when CN1-42 input signal is ON (closed).
3 Enable reverse drive when CN1-43 input signal is ON (closed).
4 Enable reverse drive when CN1-44 input signal is ON (closed).
5 Enable reverse drive when CN1-45 input signal is ON (closed).
6 Enable reverse drive when CN1-46 input signal is ON (closed).
7 Set the signal to always prohibit reverse drive.
8 Set the signal to always enable reverse drive.
9 Enable reverse drive when CN1-40 input signal is OFF (open).
A Enable reverse drive when CN1-41 input signal is OFF (open).
B Enable reverse drive when CN1-42 input signal is OFF (open).
C Enable reverse drive when CN1-43 input signal is OFF (open).
D Enable reverse drive when CN1-44 input signal is OFF (open).
E Enable reverse drive when CN1-45 input signal is OFF (open).
F Enable reverse drive when CN1-46 input signal is OFF (open).
n.X
/ALM-RST (Alarm Reset) Signal Allocation Reference
0
Active on signal edge when CN1-40 input signal changes from
OFF (open) to ON (closed).
page 12-
42
1
Active on signal edge when CN1-41 input signal changes from
OFF (open) to ON (closed).
2
Active on signal edge when CN1-42 input signal changes from
OFF (open) to ON (closed).
3
Active on signal edge when CN1-43 input signal changes from
OFF (open) to ON (closed).
4
Active on signal edge when CN1-44 input signal changes from
OFF (open) to ON (closed).
5
Active on signal edge when CN1-45 input signal changes from
OFF (open) to ON (closed).
6
Active on signal edge when CN1-46 input signal changes from
OFF (open) to ON (closed).
7 Reserved setting (Do not use.)
8 The signal is always inactive.
9
Active on signal edge when CN1-40 input signal changes from ON
(closed) to OFF (open).
A
Active on signal edge when CN1-41 input signal changes from ON
(closed) to OFF (open).
B
Active on signal edge when CN1-42 input signal changes from ON
(closed) to OFF (open).
C
Active on signal edge when CN1-43 input signal changes from ON
(closed) to OFF (open).
D
Active on signal edge when CN1-44 input signal changes from ON
(closed) to OFF (open).
E
Active on signal edge when CN1-45 input signal changes from ON
(closed) to OFF (open).
F
Active on signal edge when CN1-46 input signal changes from ON
(closed) to OFF (open).
n.X
/P-CL (Forward External Torque Limit Input) Signal Allocation Reference
0 to F
The allocations are the same as the /S-ON (Servo ON) signal allocations.
page 6-64
n.X
/N-CL (Reverse External Torque Limit Input) Signal Allocation Reference
0 to F The allocations are the same as the /S-ON (Servo ON) signal allocations.
page 6-64