No.
n.X
/ZCLAMP (Zero Clamping Input) Signal Allocation
Applicable
Motors
Reference
0 Active when CN1-40 input signal is ON (closed).
All page 6-25
1 Active when CN1-41 input signal is ON (closed).
2 Active when CN1-42 input signal is ON (closed).
3 Active when CN1-43 input signal is ON (closed).
4 Active when CN1-44 input signal is ON (closed).
5 Active when CN1-45 input signal is ON (closed).
6 Active when CN1-46 input signal is ON (closed).
7 The signal is always active.
8 The signal is always inactive.
9 Active when CN1-40 input signal is OFF (open).
A Active when CN1-41 input signal is OFF (open).
B Active when CN1-42 input signal is OFF (open).
C Active when CN1-43 input signal is OFF (open).
D Active when CN1-44 input signal is OFF (open).
E Active when CN1-45 input signal is OFF (open).
F Active when CN1-46 input signal is OFF (open).
n.X
/INHIBIT (Reference Pulse Inhibit Input) Signal Allocation
Applicable
Motors
Reference
0 to F
The allocations are the same as the /ZCLAMP
(Zero Clamping Input) signal allocations.
All page 6-40
n.X
/G-SEL (Gain Selection Input) Signal Allocation
Applicable
Motors
Reference
0 to F
The allocations are the same as the /ZCLAMP
(Zero Clamping Input) signal allocations.
All page 8-66
n.X
/P-DET (Polarity Detection Input) Signal Allocation
Applicable
Motors
Reference
0 to F
The allocations are the same as the /ZCLAMP
(Zero Clamping Input) signal allocations.
Linear page 5-27