14.1 List of Parameters
14.1.2 List of Parameters
14-32
Pn534 2
Program Jogging Accel-
eration/Deceleration
Time
2 to 10,000 1 ms 100 All
Immedi-
ately
Setup
page
7-20
Pn535 2
Program Jogging Wait-
ing Time
0 to 10,000 1 ms 100 All
Immedi-
ately
Setup
page
7-20
Pn536 2
Program Jogging Num-
ber of Movements
0 to 1,000 1 time 1 All
Immedi-
ately
Setup
page
7-20
Pn550 2
Analog Monitor 1 Offset
Voltage
-10,000 to
10,000
0.1 V 0 All
Immedi-
ately
Setup
page
9-8
Pn551 2
Analog Monitor 2 Offset
Voltage
-10,000 to
10,000
0.1 V 0 All
Immedi-
ately
Setup
page
9-8
Pn552 2
Analog Monitor 1 Mag-
nification
-10,000 to
10,000
× 0.01 100 All
Immedi-
ately
Setup
page
9-8
Pn553 2
Analog Monitor 2 Mag-
nification
-10,000 to
10,000
× 0.01 100 All
Immedi-
ately
Setup
page
9-8
Pn55A 2
Power Consumption
Monitor Unit Time
1 to 1,440 1 min 1 All
Immedi-
ately
Setup
−
Pn560 2
Residual Vibration
Detection Width
1 to 3,000 0.1% 400 All
Immedi-
ately
Setup
page
8-56
Pn561 2
Overshoot Detection
Level
0 to 100 1% 100 All
Immedi-
ately
Setup
page
8-24,
page
8-35
Pn580 2 Zero Clamping Level 0 to 10,000 1 mm/s 10 Linear
Immedi-
ately
Setup
page
6-25
Pn581 2 Zero Speed Level 1 to 10,000 1 mm/s 20 Linear
Immedi-
ately
Setup
page
6-11
Pn582 2
Speed Coincidence
Detection Signal Output
Width
0 to 100 1 mm/s 10 Linear
Immedi-
ately
Setup
page
6-27
Pn583 2
Brake Reference Out-
put Speed Level
0 to 10,000 1 mm/s 10 Linear
Immedi-
ately
Setup
page
5-36
Pn584 2
Speed Limit Level at
Servo ON
0 to 10,000 1 mm/s 10000 Linear
Immedi-
ately
Setup
page
8-8
Pn585 2
Program Jogging Move-
ment Speed
1 to 10,000 1 mm/s 50 Linear
Immedi-
ately
Setup
page
7-20
Pn586 2
Motor Running Cooling
Ratio
0 to 100
1%/
Max.
speed
0Linear
Immedi-
ately
Setup
−
Pn600 2
Regenerative Resistor
Capacity
*3
Depends on
model.
*4
10 W 0 All
Immedi-
ately
Setup
page
5-57
Pn601 2
Dynamic Brake Resis-
tor Allowable Energy
Consumption
0 to 65,535 10 J 0 All
After
restart
Setup
*5
Pn603 2
Regenerative Resis-
tance
0 to 65,535 10 mΩ 0All
Immedi-
ately
Setup
page
5-57
Pn604 2
Dynamic Brake Resis-
tance
0 to 65,535 10 mΩ 0All
After
restart
Setup
*5
Pn61A
2
Overheat Protection
Selections
0000 hex to
0003 hex
−
0000
hex
Linear
After
restart
Setup
page
6-109
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X Overheat Protection Selection
0 Disable overheat protection.
1
Use overheat protection in the Yaskawa Linear Servomotor.
*6
2
Monitor a negative voltage input from a sensor attached to the machine and
use overheat protection.
3
Monitor a positive voltage input from a sensor attached to the machine and
use overheat protection.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)