B
n F2: Analog Input Card (AI-A3)
F1-19
(3AEH)
dv4 Detection Selection
0: Disabled
n: Number of pulses that the A and B pulse are reversed that triggers dv4 detection.
Default: 128
Min: 0
Max: 5000
175
F1-20
(3B4H)
PG Option Card Disconnect
Detection 1
0: Disabled
1: Enabled
Default: 1
Min: 0
Max: 1
175
F1-21
(3BCH)
PG 1 Signal Selection
0: A pulse detection
1: AB pulse detection
Default: 0
Min: 0
Max: 1
175
F1-30
(3AAH)
PG Card Option Port for Motor 2
Selection
Sets the port for the PG option card used by motor 2.
0: CN5-C
1: CN5-B
Default: 1
Min: 0
Max: 1
175
F1-31
(3B0H)
PG 2 Pulses Per Revolution
Sets the number of pulses for a PG option card connected to port CN5-B.
Default: 1024 ppr
Min: 0 ppr
Max: 60000 ppr
173
F1-32
(3B1H)
PG 2 Rotation Selection
0: Pulse A leads
1: Pulse B leads
Default: 0
Min: 0
Max: 1
174
F1-33
(3B2H)
PG 2 Gear Teeth 1
Sets the gear ratio between the motor shaft and the encoder (PG).
A gear ratio of 1 will be used if either of these parameters is set to 0.
Default: 0
Min: 0
Max: 1000
174
F1-34
(3B3H)
PG 2 Gear Teeth 2
Default: 0
Min: 0
Max: 1000
174
F1-35
(3BEH)
PG 2 Division Rate for Pulse
Monitor
Sets the division ratio for the pulse monitor used of the PG option card 2 installed to port CN5-
B. By setting “xyz”, the division ratio becomes = [(1 + x) / yz].
Default: 1
Min: 1
Max: 132
174
F1-36
(3B5H)
PG Option Card Disconnect
Detection 2
0: Disabled
1: Enabled
Default: 1
Min: 0
Max: 1
175
F1-37
(3BDH)
PG 2 Signal Selection
0: A pulse detection
1: AB pulse detection
Default: 0
Min: 0
Max: 1
175
<34> Default setting is determined by the control mode (A1-02).
No.(Addr.) Name Description Setting Page
F2-01
(38FH)
Analog Input Option Card
Operation Selection
0: Option card input terminals V1, V2, and V3 replace drive input terminals A1, A2, and A3.
1: Input signals to terminals V1, V2, and V3 are added together to create the frequency
reference.
Default: 0
Min: 0
Max: 1
176
F2-02
(368H)
Analog Input Option Card Gain
Sets the gain for the input signal to the analog card.
Default: 100.0%
Min: -999.9%
Max: 999.9%
176
F2-03
(369H)
Analog Input Option Card Bias
Sets the bias for the input signal to the analog card.
Default: 0.0%
Min: -999.9%
Max: 999.9%
176
No.(Addr.) Name Description Setting Page
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
All Modes