6 Jog reference selection
Closed: Jog frequency reference (d1-17) selected. Jog has priority over all other reference sources.
183
7 Accel/decel time selection 1
Used to switch between accel/decel time 1 (set in C1-01, C1-02) and accel/decel time 2 (set in C1-03, C1-04).
183
8 Baseblock command (N.O.)
Closed: No drive output
183
9 Baseblock command (N.C.)
Open: No drive output
183
A Accel/decel ramp hold
Open: Accel/decel is not held
Closed: The drive pauses during acceleration or deceleration and maintains the output frequency.
183
B Drive overheat alarm (oH2)
Closed: Closes when an oH2 alarm occurs
183
C Analog terminal input selection
Open: Function assigned by H3-14 is disabled.
Closed: Function assigned by H3-14 is enabled.
184
D PG encoder disable
Open: Speed feedback for V/f Control with PG is enabled.
Closed: Speed feedback disabled.
184
E ASR integral reset
Open: PI control
Closed: Integral reset
184
F Through mode
Select this setting when using the terminal in a pass-through mode. The terminal does not trigger a drive function
but can be used as digital input for the controller the drive is connected to.
184
10 Up command
The drive accelerates when the Up command terminal closes, and decelerates when the Down command closes.
When both terminals are closed or both are open, the drive holds the frequency reference. The Up and Down
commands must always be used in conjunction with one another.
184
11 Down command 184
12 Forward Jog
Closed: Runs forward at the Jog frequency d1-17.
185
13 Reverse Jog
Closed: Runs reverse at the Jog frequency d1-17.
185
14 Fault reset
Closed: Resets faults if the cause is cleared and the Run command is removed.
185
15 Fast Stop (N.O.)
Closed: Decelerates at the Fast Stop time set to C1-09.
185
16 Motor 2 selection
Open: Motor 1 (E1-, E2-)
Closed: Motor 2 (E3-, E4-)
186
17 Fast Stop (N.C.)
Open: Decelerates to stop at the Fast Stop time set to C1-09.
185
18 Timer function input
Triggers the timer set up by parameters b4-01 and b4-02. Must be set in conjunction with the timer function output
(H2- = 12).
186
19 PID disable
Open: PID control enabled
Closed: PID control disabled
186
1A Accel/decel time selection 2
Used in conjunction with an input terminal set for “Accel/decel time selection 1” (H1- = 7), and allows the
drive to switch between accel/decel times 3 and 4.
186
H1 Multi-Function Digital Input Selections
H1-
Setting
Function Description Page
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
All Modes
All Modes
All Modes
All Modes
All Modes
All Modes
OLV/PM AOLV/PM
CLV
V/f w/PG
CLV/PM
V/f OLV
All Modes
All Modes
All Modes
All Modes