B.5 Parameter Defaults Determined by Drive Model (o2-04) and Duty Rating (C6-01)
428 YASKAWA ELECTRIC SIEP C710616 30B YASKAWA AC Drive T1000A Technical Manual
Table B.6 400 V Class Drives Default Settings by Drive Capacity and ND/HD Setting
No. Name Unit Default Settings
– Model CIMR-T – 4A0002 4A0004 4A0005 4A0007
C6-01 Drive Duty Selection –
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04 Drive Model Selection Hex. 92 93 94 95
E2-11 (E4-11) Motor rated power kW 0.4 0.75 0.75 1.5 1.5 2.2 2.2 3.0
b3-04 V/f Gain during Speed Search % 100 100 100 100 100 100 100 100
b3-06 Output Current 1 during Speed Search – 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b8-03 Energy Saving Control Filter Time Constant s 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50
b8-04 Energy Saving Coefficient Value – 576.4 447.4 447.4 338.8 338.8 313.6 313.6 265.7
C5-17 (C5-37) Motor Inertia
kgm
2
0.0015 0.0028 0.0028 0.0068 0.0068 0.0088 0.0088 0.0158
C6-02 Carrier Frequency Selection – 1 1 1 1 1 1 1 1
E2-01 (E4-01) Motor Rated Current A 1 1.6 1.6 3.1 3.1 4.2 4.2 5.7
E2-02 (E4-02) Motor Rated Slip Hz 2.9 2.6 2.6 2.5 2.5 3 3 2.7
E2-03 (E4-03) Motor No-Load Current A 0.6 0.8 0.8 1.4 1.4 1.5 1.5 1.9
E2-05 (E4-05) Motor Line-to-Line Resistance Ω 38.198 22.459 22.459 10.1 10.1 6.495 6.495 4.360
E2-06 (E4-06) Motor Leakage Inductance % 18.2 14.3 14.3 18.3 18.3 18.7 18.7 19
E2-10 (E4-10) Motor Iron Loss for Torque Compensation W 14 26 26 53 53 77 77 105
E5-01 Motor Code Selection Hex. 1232 1232 1233 1233 1235 1235 1236 1236
L2-02 Momentary Power Loss Ride-Thru Time s 0.1 0.1 0.2 0.2 0.3 0.3 0.5 0.5
L2-03 Momentary Power Loss Min. Baseblock Time s 0.2 0.3 0.3 0.4 0.4 0.5 0.5 0.5
L2-04 Momentary Power Loss Voltage Recovery Time s 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
L8-02 Overheat Alarm Level °C 110 110 110 110 110 110 110 110
L8-35 Installation Method Selection – 2 2 2 2 2 2 2 2
L8-38 Carrier Frequency Reduction Selection – 2 2 2 2 2 2 2 2
n1-03 Hunting Prevention Time Constant ms 10 10 10 10 10 10 10 10
n5-02 Motor Acceleration Time s 0.178 0.142 0.142 0.166 0.166 0.145 0.145 0.145
n9-12 On-Delay Compensation Time μs 1.5 1.5 1.5 1.5 1.7 1.7 1.7 1.7
S6-01 DC Bus Capacity μF 250 250 250 250 250 250 375 375
S6-02 Motor Acceleration Time s 0.178 0.142 0.142 0.166 0.166 0.145 0.145 0.145
No. Name Unit Default Settings
– Model CIMR-T – 4A0009 4A0011 4A0018 4A0023
C6-01 Drive Duty Selection –
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04 Drive Model Selection Hex. 96 97 99 9A
E2-11 (E4-11) Motor Rated Power kW 3.0 3.7 3.7 5.5 5.5 7.5 7.5 11
b3-04 V/f Gain during Speed Search % 100 100 100 100 100 100 100 100
b3-06 Output Current 1 during Speed Search – 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
b8-03 Energy Saving Control Filter Time Constant s 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50
b8-04 Energy Saving Coefficient Value – 265.7 245.8 245.8 189.5 189.5 145.38 145.38 140.88
C5-17 (C5-37) Motor Inertia
kgm
2
0.0158 0.0158 0.0158 0.0255 0.026 0.037 0.037 0.053
C6-02 Carrier Frequency Selection – 1 1 1 1 1 1 1 1
E2-01 (E4-01) Motor Rated Current A 5.7 7 7 9.8 9.8 13.3 13.3 19.9
E2-02 (E4-02) Motor Rated Slip Hz 2.7 2.7 2.7 1.5 1.5 1.3 1.3 1.7
E2-03 (E4-03) Motor No-Load Current A 1.9 2.3 2.3 2.6 2.6 4 4 5.6
E2-05 (E4-05) Motor Line-to-Line Resistance Ω 4.360 3.333 3.333 1.595 1.595 1.152 1.152 0.922
E2-06 (E4-06) Motor Leakage Inductance % 19 19.3 19.3 18.2 18.2 15.5 15.5 19.6
E2-10 (E4-10) Motor Iron Loss for Torque Compensation W 105 130 130 193 193 263 263 385
E5-01 Motor Code Selection Hex. FFFF FFFF 1238 1238 123A 123A 123B 123B
L2-02 Momentary Power Loss Ride-Thru Time s 0.5 0.5 0.5 0.5 0.8 0.8 1 1
L2-03 Momentary Power Loss Min. Baseblock Time s 0.5 0.6 0.6 0.7 0.7 0.8 0.8 0.9
L2-04 Momentary Power Loss Voltage Recovery Time s 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
L8-02 Overheat Alarm Level °C 110 110 110 110 110 110 115 115
L8-35 Installation Method Selection – 2 2 2 2 2 2 2 2
L8-38 Carrier Frequency Reduction Selection – 2 2 2 2 2 2 2 2
n1-03 Hunting Prevention Time Constant ms 10 10 10 10 10 10 10 10
n5-02 Motor Acceleration Time s 0.145 0.154 0.154 0.168 0.168 0.175 0.175 0.265
n9-12 On-Delay Compensation Time μs 1.5 1.5 1.5 1.5 1.5 1.5 1.7 1.7
S6-01 DC Bus Capacity μF 675 675 675 675 480 480 590 590
S6-02 Motor Acceleration Time s 0.145 0.154 0.154 0.168 0.168 0.175 0.175 0.265