Measured Value Read Commands (INITiate, FETCh, READ, and MEASure groups)
:INITiate
Clears the measured value and prepares the GS200 to
perform the next measurement. 13-17
:FETCh?
Queries the measured result. 13-17
:READ?
Clears the measured value, prepares the GS200 to perform the next
measurement, and queries the measured result. 13-17
:MEASure?
Clears the measured value, prepares the GS200 to perform the next
measurement, generates a measurement trigger, and queries the
measured result. 13-17
Store/Recall Commands (TRACe group)
:TRACe
[:STATe]/?
Sets or queries the storage state (on/off). 13-18
:FILE
:CREate/?
Sets or queries the result file generation feature (on/off). 13-18
:POINts/?
Sets or queries the storage count. 13-18
:ACTual?
Queries the number of stored results. 13-18
:DATA
:FORMat/?
Sets or queries the load format for stored data. 13-18
:ENDian/?
Sets or queries the byte order for when the load format for stored data
is binary. 13-18
:READ? [TM|SF|SL|MF|ML]
Loads stored data. 13-19
:STATistics?
Loads statistical values for stored data. 13-19
External I/O Commands (ROUTe group)
:ROUTe
:BNCO/?
Sets or queries the output BNC signal. 13-20
:BNCI/?
Sets or queries the input BNC signal. 13-20
System Commands (SYSTem group)
:SYSTem
:SETup
:SAVE
Saves setup data. 13-22
:LOAD
Restores setup data. 13-22
:DELete
Deletes a setup file. 13-22
:CATalog?
Queries the list of setup files. 13-22
:PON/?
Sets or queries the setup data at power-on. 13-22
:DISPlay
[:STATe]/?
Sets or queries the display state (on/off). 13-21
:BRIGht/?
Sets or queries the display brightness. 13-21
:TEXT/?
Displays or queries the user message. 13-21
:CLEar
Clears the user message display. 13-21
:NORMal
Displays the main screen. 13-21
:BEEPer/?
Sets or queries the beep sound (on/off). 13-22
:CLOCk
:TZONe/?
Sets or queries the time zone. 13-21
:DATE/?
Sets or queries the date. 13-21
:TIME/?
Sets or queries the time. 13-21
:ADJust
Corrects the time by ±30 seconds. 13-22
:ERRor?
Queries and clears the most recent error information. 13-22
:LOCal
Switches the GS200 to local mode. 13-22
:REMote
Switches the GS200 to remote mode. 13-22
:LFRequency?
Queries the line frequency. 13-22
13.2 Commands
13-8
IM GS210-01EN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA GS200 and is the answer not in the manual?

YOKOGAWA GS200 Specifications

General IconGeneral
BrandYOKOGAWA
ModelGS200
CategoryPower Supply
LanguageEnglish

Related product manuals