EasyManua.ls Logo

YOKOGAWA GS200 - 13.2 Commands

YOKOGAWA GS200
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13.2 Commands
13.2.1 List of Commands
Command Function Page
Output Commands (OUTPut group)
:OUTPut
[:STATe]/?
Sets or queries the output state (on/off). 13-10
Source Commands (SOURce group)
:SOURce
:FUNCtion/?
Sets or queries the source function (voltage/current). 13-11
:RANGe/?
Sets or queries the source range. 13-11
:LEVel
[:FIX]/?
Sets or queries the source level in terms of the range that is being used. 13-11
:AUTO/?
Sets or queries the source level in terms of the most appropriate range. 13-12
:PROTection
:VOLTage/?
Sets or queries the voltage limiter level. 13-12
:CURRent/?
Sets or queries the current limiter level. 13-12
Program Commands (PROGram group)
:PROGram
:REPeat
[:STATe]/?
Sets or queries the program execution repetition mode (on/off). 13-13
:INTerval/?
Sets or queries the program execution timer’s period. 13-13
:SLOPe/?
Sets or queries the program slope time. 13-13
:TRIGger/?
Sets or queries the program trigger. 13-13
:EDIT
:STARt
Starts program memory editing. 13-13
:END
Ends program memory editing. 13-13
:SAVE
Saves the program memory as a program file. 13-13
:LOAD/?
Loads a program file into program memory. 13-13
:DELete
Deletes a program file. 13-14
:DEFine
Creates a program file. 13-14
:MEMory
Writes a program file to program memory. 13-14
:CATalog?
Queries the list of program files. 13-14
:RUN
Executes a program (RUN execution). 13-14
:STEP
Executes a program (STEP execution). 13-14
:HOLD
Pauses and resumes program execution. 13-14
:PAUSe
Pauses program execution. 13-14
:CONTinue
Resumes program execution. 13-14
:COUNt/?
Sets or queries the step that the current program begins execution at. 13-14
Measurement Commands (SENSe group)
:SENSe
[:STATe]/?
Sets or queries the measurement feature (on/off). 13-15
:NPLC/?
Sets or queries the measurement integration time in terms of PLC. 13-15
:DELay/?
Sets or queries the measurement delay time. 13-15
:TRIGger/?
Sets or queries the measurement trigger. 13-15
:INTerval/?
Sets or queries the measurement timer’s period. 13-15
:NULL
[:STATe]/?
Sets or queries the NULL computation feature (on/off). 13-15
:ZERO
:EXECute
Executes measurement zero calibration. 13-16
:REMote/?
Sets or queries the wiring system (on = 4W/off = 2W). 13-16
:GUARd/?
Sets or queries the guard state (on/off). 13-16
13-7
IM GS210-01EN
Communication Commands
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
App
Index

Table of Contents

Related product manuals