Maintenance, Troubleshooting & Technical Specifications 3 - 5
Digital Scanner emits a
low/high/low/high beep sequence
while it is being programmed.
Out of ADF parameter storage
space.
Erase all rules and re-program with
shorter rules.
Digital Scanner emits long low/long
high beeps.
Input error, incorrect bar code or
Cancel
bar code was scanned.
Scan the correct numeric bar codes
within range for the parameter
programmed.
Page timeout; remote device is
out of range/not powered.
Move the digital scanner back into
range of the remote device; try to
re-connect; check remote device
configuration.
Digital Scanner emits long low/long
high/long low/long high beeps.
Out of host parameter storage
space.
Scan
Default Parameters on page
5-5
.
Out of memory for ADF rules. Reduce the number of ADF rules or the
number of steps in the ADF rules.
Connection attempt was rejected
by remote device.
Free up remote device resources.
Digital Scanner emits
high/high/high/low beeps.
RS-232 receive error. Normal during host reset. Otherwise,
set the digital scanner's RS-232 parity
to match the host setting.
Digital Scanner emits high/low
beeps.
The digital scanner is buffering
Code 39 data.
Or
Keyboard parameter selected.
Normal.
Or
Enter value using bar code keypad.
Bluetooth disconnection event. Move the digital scanner back into
range of the remote device.
In Master (SPP) mode, re-pair the
digital scanner and cradle by scanning
the
PAIR
bar code on the cradle; check
cradle power.
In Slave (SPP/HID) mode, reestablish
connection between the digital scanner
and remote device from the remote
device side.
Digital Scanner emits three long high
beeps.
Code 39 buffer is full. Scan the Code 39 bar code without a
leading space or scan
Do Not Buffer
Code 39
on
Code 39 Buffering - Scan
& Store on page 15-39
to transmit
stored Code 29 data.
Digital Scanner emits four high
beeps on trigger release.
Low battery. Place digital scanner in cradle to
charge the battery.
Table 3-1
Troubleshooting (Continued)
Problem Possible Causes Possible Solutions