SYSTEM START UP
Section 3, Page 3 May 2002
SMALL CASE GDP-32
II
T (UP TO 6 CHANNELS)
Front Panel Access
1. With the case lid open, unscrew the 12 screws from the top panel and carefully
remove the panel (be careful to not stress the connecting wires).
2. Verify the each board is firmly mounted and that all cables are firmly connected to
the appropriate boards; there should be no unconnected cables.
3. Replace the top panel, being careful to not crimp any cable or wires, and replace the
12 securing screws.
Side Panel Access
1. Remove the 10 securing screws from the Analog side panel.
2. Check all cables.
3. Verify that each board is firmly mounted and that all cables are firmly connected to
the appropriate boards. Verify that the retaining bar across the bottom of the card
cage is firmly attached.
NOTE: All 6-channel GDP-32
II
’s are pre-wired for 6 channels regardless of how many
channels were ordered.
4. Replace the Analog side panel, being careful to not crimp any cable or wires, and
replace the 10 securing screws.
NOTE: Turn the screws until the head touches the top of the panel, then turn it ¼ turn
more.