GDP-32
II
INSTRUCTION MANUAL
May 2002 Section 3, Page 6
3.4 CHARGING BATTERIES
SINGLE UNIT CHARGERS
There is a selector switch for either 115 or 230 volts on the base or front of single unit chargers.
Select the voltage according to the power system used by the country in which you are working
(the charger will work for both 50 and 60 Hz).
WARNING: Improper switch selection may result in damage to your battery charger and/or to
the receiver batteries.
1. Plug the charger power cable into a power outlet. The POWER ON light on the
charger should turn on.
2. Connect the charging cable from the charger to the BATTERY CHARGE port on the
receiver Control I/O panel. Make sure there is a good connection between the
military plug and the BATTERY CHARGE port. The batteries are charging if the
FAST CHARGE light on the charger is illuminated. Batteries are fully charged when
the FAST CHARGE light turns off completely.
UC-2 UNIVERSAL CHARGER
The UC-2 battery charger works with 85 to 264 VAC and 45 to 440 Hz.
1. Plug the charger cable into the BATTERY CHARGER port on the GDP-32
II
.
2. Plug the UC-2 into a power outlet.
3. Turn the UC-2 on.
NOTE: The UC-2 battery charger must be turned off and turned back on again to reset
the circuitry.
The battery charging cable can be attached or detached even when the receiver is operating.
Data acquisition and system checks are not recommended while charging batteries as the charger
sometimes introduces noise to the receiver.
If you suspect a problem or if battery charging does not proceed as outlined, see Section 15 -
Maintenance.