MATHEMATICAL ALGORITHMS
Section 15, Page 7 October 2002
An example of a GRADIENT array setup:
The AB transmitter dipole is set up on grid line 52,000 N, a-spacing = 50 m, the north-south
baseline runs through the middle of the array, so that A is at -350 meters (350 W) and B is at
+350 meters (350 E). The first potential electrode as shown is located at -100 meters (100 W),
and 100 meters north of the transmitter dipole, or 52100. The data would be input as follows:
MENU 1
Ax = -350
Bx = +350
West
Ax, Ay
East
Bx, By
Rx
,
R
y
N= 1 2 3
running survey
west to east
Y
X
Dy
Dx
dx
NORTH
SOUTH
TDIP 0533 15 Mar 94 08:53:40
Array type: Gradient
Mode: Synchronous
Ax location: -350 meters
Bx location: 350 meters
Automatic Gain Mode: Noisy
Environment Type: Quiet
CONTINUE: Next menu, ESCAPE: Prev. menu