2000-OSM, F1 10-39
PUT_ACTUAL_RT(method%,component%,retention!)
PUT ACTUAL RETENTION TIME
PUT_BENCH_CONC(method%,component%,concentration!)
PUT BENCHMK CONCENTRATION
PUT_CAL_CONC(method%,component%,concentration!)
PUT CALIB CONCENTRATION
PUT_CC(method%,component%,concentration!)
PUT COMP CONCENTRATION
PUT_COMP_NAME(method%,component%,name$)
PUT COMPONENT NAME
PUT_EXPECTED_RT(method%,component%,retention%)
PUT EXPECTED RETENTION TIME
PUT_MULTIPLIER_EXP(method%,value%) PUT MULTIPLIER EXPONENT
PUT_PRESS(zone%,set point!,ramp rate!) PUT PRESSURE OF A ZONE
PUT_REPORT_TYPE(type%) PUT REPORT TYPE
PUT_RF(method%,component%,response!) PUT RESPONSE FACTOR
PUT_TEMP(zone%,set point!,ramp rate!) PUT TEMPERATURE OF A ZONE
RAI(channel%) READ ANALOG INPUT
RDI(channel%,type%) READ DIGITAL INPUT
REPORT_TYPE REPORT TYPE
RQANA(stream%) REQUEST ANALYSIS
RQBEN(method%) REQUEST BENCHMARK
RQCAL(method%) REQUEST CALIBRATION
SENSOR_ALARM SENSOR ALARM
SET_BASIC_ALARM(alarm%) SET BASIC ALARM
SET_BASIC_COMP_ALARM(method%,component%,alarm%)
SET BASIC COMPONENT ALARM
START START ANALYSIS
STATUS(stream%) STREAM STATUS
STOP(n%) STOP ANALYSIS
TCF_ERROR_ALARM TCF ERROR ALARM
TIME$ TIME
TOT_PK_RAW_AREA TOTAL PEAK RAW AREA
VALVE(number%,state%) VALVE
WDO(channel%,state%) WRITE DIGITQL OUTPUT
WTO(channel%,state%) WRITE TREND OUTPUT
ZERO_OUTSTANDING_REQUESTS ZERO OUTSTANDING REQUESTS
SIM DIS (Only) Commands
ADD_TCF(method%,time%,function$,value$) ADD TCF
DELETE_ALL_GATE_TCFS(method%) DELETE ALL GATE TCFS
DELETE_ALL_TCFS(method%,function$) DELETE ALL TCFS OF A TYPE
GET_ASTM GET ASTM
GET_BLEND(stream%) GET BLEND
GET_FACT_TBL(array!,table%) GET CORREL FACTOR TABLE
GET_MAX_PEAK_PARM GET MAX PEAK PARAMETER
GET_PEAK_TYPE GET PEAK TYPE PARAMETER
GET_POFF(temperature!,time_vs_bp_table%) GET % OFF FOR A TEMPERATURE
GET_POFF_TBL(array!,table%) GET % OFF TABLE
GET_TEMP(percent_off!,time_vs_bp_table%) GET TEMPERATURE FOR A % OFF
GET_TEMP_TBL(array!,table%) GET TEMPERATURE TABLE
GET_TVSBP_TBL(array!,table%) GET TIME VS. BOIL POINT TABLE
LEN_FACT_TBL(table%) LENGTH OF CORREL FACTOR
LEN_POFF_TBL(table%) LENGTH OF % OFF TABLE
LEN_TEMP_TBL(table%) LENGTH OF TEMP TABLE
LEN_TVSBP_TBL(table%) LENGTH OF TIME VS BOIL POINT