Installation & Maintenance Manual 210 Document #: LTRT-40111
Mediant 1000B SBA
29.2 Running the Process Immediately or Upon User
Confirmation
You can configure the SBA upgrade and recovery to start automatically (immediately) or
only upon user confirmation, by using the Automatic parameter.
Upon Confirmation: To start the SBA upgrade and recovery only after user
confirmation, set the Automatic parameter to 0, as shown below:
[Execution] Automatic= 0
Once the process starts, you are prompted (via the console) to confirm the SBA
upgrade and recovery.
Automatic (recommended and default): To start the SBA upgrade and recovery
automatically (without confirmation), set the Automatic parameter to 1, as shown
below:
[Execution] Automatic= 1
With this setting, the SBA upgrade and recovery starts immediately after the OSN
server boots from the USB dongle.
29.3 Checking Disk before Image Burn
You can configure the SBA upgrade and recovery to check the disk before burning the
SBA image to the OSN server, using the CheckDisk parameter. The result of this disk
check is logged to the RecoveryLog.txt file, located on the USB dongle.
Enable disk check (recommended and default): To enable disk checking before
burning the image, set the CheckDisk parameter to 0, as shown below:
[Execution] CheckDisk=0
Disable disk check: To disable disk checking before burning the image, set the
CheckDisk parameter to 1, as shown below:
[Execution] CheckDisk=1