Installation & Maintenance Manual 30. SBA Upgrade and Recovery
Version 6.8 219 Microsoft Lync Server
Figure 30-3: OSN3 LED Indication for Shut Down
Note: If you are connecting to an OSN3B and OSN4 module, see Section 5.1.3 on page
29 for more information when monitoring LEDs.
6. Remove the USB dongle from the USB port on the OSN module.
7. Power off and then power on the Mediant 1000B to reboot the OSN server; the
initialization process starts.
Notes:
This step may take a while (about 10 minutes). While the Mediant 1000B is rebooting,
DO NOT power off the Mediant 1000B.
During initialization, the OSN server restarts twice.
8. Determine the NIC that is assigned to the required Ethernet port and the
corresponding IP address, and then use this IP address to connect to the SBA (see
Section 30.4).