3. Advanced Commands
Receive (acknowledge)
Checksum
\x07
Stop
\xff
3.2.11 PiP rename layout
Description
Renames a PiP layout .
Command
Command [0]
\x12
Command [1]
\x09
Data
strOldPipname = string (old name of the layout)
strNewPipname = string of max 12 characters (new layout name)
The string is of the C– language type see chapter "1. Serial communications Basics" , "Syntax", page 9
Example
Renames the PiP layout “test” to “test2”.
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x12
Command[1]
\x09
Data[0]
\x74
Data[1]
\x65
Data[2]
\x73
Data[3]
\x74
Data[4]
\x00
Data[5]
\x74
Data[6]
\x65
Data[7]
\x73
Data[8]
\x74
Data[9]
\x32
Data[10]
\x00
Checksum
\xce
Stop
\xff