2. Basic Commands
Returned Data
signed word :
Data [0] = msb
Data [1] = lsb
Example
Reads the actual Tint value of the projector, the awnser being: \x00 \x20
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x04
Checksum
\x26
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x04
Data [0]
\x00
Data [1]
\x20
Checksum
\x46
Stop
\xff
2.7.23 Minimum Tint, Read
Description
Reads the minimum (range) Tint value of the projector
Command
Command [0]
\x26
Command [1]
\x04
Returned Data
signed word :