3. Advanced Commands
Receive (acknowledge)
Checksum
\x07
Stop
\xff
Receive (awnser)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\xa2
Data[0]
\x0a
Data[1]
\x00
Checksum
\xce
Stop
\xff
3.24 Gain Control, Increment/Decrement
Description
Increments/decrements the Gain Control value by one
Commands
increment:
Command [0]
\x22
Command [1]
\xa2
decrement:
command[0]
\x23
command[1]
\xa2
3.25 Minimum/Maximum AGC value, Read
Description
Reads the minimum/maximum AGC(Automatic Gain Control) value.
Commands
read minimum:
Command [0]
\x26
Command [1]
\xa2
read maximum:
Command[0]
\x27
Command[1]
\xa2