3. Advanced Commands
Receive (awnser)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\xa0
Data[0]
\x00
Checksum
\xc2
Stop
\xff
3.31.27 Minimum/Maximum comb filter, Read
Description
Reads the minimum/max comb filter
Commands
read minimum:
Command [0]
\x26
Command [1]
\xa0
read maximum:
Command[0]
\x27
Command[1]
\xa0
Returned Data
Data [0] = min/max value
3.31.28 Horizontal sync polarity, Increment/Decrement
Description
Increments/decrements the horizontal sync polarity by one
Commands
increment:
Command [0]
\x22
Command [1]
\xa9
decrement:
command[0]
\x23
command[1]
\xa9
3.31.29 Minimum/Maximum Horizontal sync polarity, Read
Description
Reads the minimum/max Horizontal sync polarity