3. Advanced Commands
Transmit
Data[1]
\x00
Checksum
\xcd
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
3.23 Manual Ga in Control value, Re ad
Description
Reads the actual gain control value
Command
Command [0]
\x21
Command [1]
\xa2
Returned Data
Data [0] = lsb
Data [1] = msb
Example
Reads the AGC value, being \x0A =10
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\xa2
Checksum
\xc4
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
R5976884 RLM SERIES 04/04/2006 137