3. Advanced Commands
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x20
Command[1]
\x90
Data[0]
\x00
Data[1]
\x01
Checksum
\xb2
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
3.19 AutoImage setup, Read
Description
Reads the AutoImage set up
Command
Command [0]
\x21
Command [1]
\x90
Returned Data
Unsigned word.see chapter "1. Serial communications Basics", "Data words", page 6
Data[0] = unsigned byte (msb)
Data[1] = unsigned byte (lsb)
Parameter Data[0] Data[1] Hex Value
To t al P ix el s 0000 0001
\x01
Contrast/Brightness
0000 0010
\x02
Phase 0000 0100
\x04
Start pixel/line
0000 1000
\x08
Total pixels + cont/bright
0000 0011
\x03
...
Example
reads the AutoImage set up, being :\x01 = “Total Pixels”
R5976884 RLM SERIES 04/04/2006
133