2. Basic Commands
Command
Command [0]
\x26
Command [1]
\x02
Returned Data
Data [0] = minimum Brightness value
Example
Reads the minimum Brightness value of the projector, the awnser being \x00
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x26
Command[1]
\x02
Checksum
\x29
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x26
Command[1]
\x02
Data [0]
\x00
Checksum
\x29
Stop
\xff
2.7.12 Maximum Brightness, Read
Description
Reads the Maximum (range) Brightness value of the projector
Command
Command [0]
\x27
Command [1]
\x02