EasyManuals Logo

Barco RLM series User Manual

Barco RLM series
171 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #159 background imageLoading...
Page #159 background image
3. Advanced Commands
Command [0]
\x26
Command [1]
\xa9
read maximum:
Command[0]
\x27
Command[1]
\xa9
Returned Data
Data [0] = min/max value
3.31.30 Horizontal sync polarity, Read
Description
Reads the Horizontal sync polarity setting
Command
Command [0]
\x21
Command [1]
\xa9
Returned Data
Data [0] = byte : 0 = active low ; 1 = active high ; 2 = auto (determined by ADC)
3.31.31 Horizontal sync polarity, Write
Description
Sets the Horizontal sync polarity setting in the image file.
Command
Command [0]
\x20
Command [1]
\xa9
Data
Data [0] = byte : 0 = active low ; 1 = active high ; 2 = auto (determined by ADC)
3.31.32 Sync locking, Increment/Decrement
Description
Increments/decrements the Sync locking setting by one
Commands
increment:
Command [0]
\x22
Command [1]
\xab
decrement:
command[0]
\x23
command[1]
\xab
R5976884 RLM SERIES 04/04/2006 157

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Barco RLM series and is the answer not in the manual?

Barco RLM series Specifications

General IconGeneral
BrandBarco
ModelRLM series
CategoryProjector
LanguageEnglish

Related product manuals