3. Advanced Commands
Command [0]
\x26
Command [1]
\xa9
read maximum:
Command[0]
\x27
Command[1]
\xa9
Returned Data
Data [0] = min/max value
3.31.30 Horizontal sync polarity, Read
Description
Reads the Horizontal sync polarity setting
Command
Command [0]
\x21
Command [1]
\xa9
Returned Data
Data [0] = byte : 0 = active low ; 1 = active high ; 2 = auto (determined by ADC)
3.31.31 Horizontal sync polarity, Write
Description
Sets the Horizontal sync polarity setting in the image file.
Command
Command [0]
\x20
Command [1]
\xa9
Data
Data [0] = byte : 0 = active low ; 1 = active high ; 2 = auto (determined by ADC)
3.31.32 Sync locking, Increment/Decrement
Description
Increments/decrements the Sync locking setting by one
Commands
increment:
Command [0]
\x22
Command [1]
\xab
decrement:
command[0]
\x23
command[1]
\xab
R5976884 RLM SERIES 04/04/2006 157