2. Basic Commands
Command
Command [0]
\x21
Command [1]
\x03
Returned Data
Data [0] =Saturation value
Example
Reads the actual Saturation value of the projector, the awnser being \x20
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x03
Checksum
\x25
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x03
Data [0]
\x20
Checksum
\x45
Stop
\xff
2.7.17 Minimum Saturation, Read
Description
Reads the minimum (range) Saturation value of the projector
Command
Command [0]
\x26
Command [1]
\x03
R5976884 RLM SERIES 04/04/2006 31