2. Basic Commands
2.7.5 Minimum Contrast, Read
Description
Reads the minimum (range) contrast value of the projector
Command
Command [0]
\x26
Command [1]
\x01
Returned Data
Data [0] = minimum contrast value
Example
Reads the minimum contrast value of the projector, the awnser being \x00
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x26
Command[1]
\x01
Checksum
\x28
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x26
Command[1]
\x01
Data [0]
\x00
Checksum
\x28
Stop
\xff
2.7.6 Maximum Contrast, Read
Description
Reads
the Maximum (range) contrast value of the projector
24
R5976884 RLM SERIES 04/04/2006