3. Advanced Commands
Receive (Awnser)
Data [6]
\x63
Data [7]
\x72
Data [8]
\x65
Data [9]
\x65
Data [10]
\x6e
Data [11]
\x00
Data [0]
\x32
Data [1]
\x62
Data [2]
\x76
Data [3]
\x32
Data [4]
\x20
Data [5]
\x72
Data [6]
\x61
Data [7]
\x73
Data [8]
\x74
Data [9]
\x65
Data [10]
\x72
Data [11]
\x00
Checksum
\x44
Stop
\xff
3.2.7 PiP current layout, Read
Description
Returns the current PiP layout.
Command
Command [0]
\x12
Command [1]
\x05
Returned Data
strPipname = string
The string is o f the C-langu age typ e see chapter "1. Serial communications Basics", "Syntax", page 9
Example
Reads the actual PiP layout , result = Full screen.