EasyManua.ls Logo

Barco RLM series - Minimum;Maximum Horizontal Sync Locking, Read; Sync Locking, Read; Sync Locking, Write; C Diagnosis, Read

Barco RLM series
171 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3. Advanced Commands
3.31.33 Minim um/Maximum Horizontal Sync locking, Read
Description
Reads the minimum/max Sync locking
Commands
read minimum:
Command [0]
\x26
Command [1]
\xab
read maximum:
Command[0]
\x27
Command[1]
\xab
Returned Data
Data [0] = byte : 0 = slow ; 1 = fast
3.31.34 Sync locking, Read
Description
Reads the Sync locking setting
Command
Command [0]
\x21
Command [1]
\xab
Returned Data
Data [0] = byte : 0 = slow ; 1 = fast
3.31.35 Sync locking, Write
Description
Sets the Sync locking (fast or slow)
Command
Command [0]
\x20
Command [1]
\xab
Data
Data [0] = byte : 0 = slow ; 1 = fast
3.32 I
2
C diagnosis, Read
Description
Reads the I
2
C diagnosis.
Command
Command [0]
\x81
Command [1]
\x01
158 R5976884 RLM SERIES 04/04/2006