3. Advanced Commands
3.31.33 Minim um/Maximum Horizontal Sync locking, Read
Description
Reads the minimum/max Sync locking
Commands
read minimum:
Command [0]
\x26
Command [1]
\xab
read maximum:
Command[0]
\x27
Command[1]
\xab
Returned Data
Data [0] = byte : 0 = slow ; 1 = fast
3.31.34 Sync locking, Read
Description
Reads the Sync locking setting
Command
Command [0]
\x21
Command [1]
\xab
Returned Data
Data [0] = byte : 0 = slow ; 1 = fast
3.31.35 Sync locking, Write
Description
Sets the Sync locking (fast or slow)
Command
Command [0]
\x20
Command [1]
\xab
Data
Data [0] = byte : 0 = slow ; 1 = fast
3.32 I
2
C diagnosis, Read
Description
Reads the I
2
C diagnosis.
Command
Command [0]
\x81
Command [1]
\x01