3. Advanced Commands
Command
Command [0]
\x21
Command [1]
\x9c
Returned Data
Data [0] = unsigned byte
byte value:
\x00 = short ; \x01 = long
Example
Reads the Automatic startup, being \x00 = short
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x9c
Checksum
\xbe
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (awnser)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x9c
Data[0]
\x00
Checksum
\xbe
Stop
\xff
3.28 Data
input format, Increment/Decrement
Des
cription
Increments/decrements the Data input format setting.