2. Basic Commands
Command
Command [0]
\x21
Command [1]
\x70
Returned Data
Data [0] = Gamma value
Example
Reads the actual Gamma value of the projector, the awnser being \x11
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x70
Checksum
\x92
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x70
Data [0]
\x11
Checksum
\xa3
Stop
\xff
2.7.29 Minimum Gamma, Read
Description
Reads the minimum (range) Gamma value of the projector
Command
Command [0]
\x26
Command [1]
\x70