3. Advanced Commands
Returned Data
Data [0] = min/max value
3.26 Automatic Gain C ontrol interval, Write
Description
Sets the AGC to short or long.
Command
Command [0]
\x20
Command [1]
\x9c
Data
Data [0] = byte type
byte value:
0=short;1=long
Example
Sets the AGC interval to “short”
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x20
Command[1]
\x9c
Data[0]
\x00
Checksum
\xbd
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
3.27 Automatic Gain Control Interval, Read
Description
Reads the AGC interval (short or long)