102 CHA NGE PARA METERS
6.8.4.2 I DYN A MIC PROFILE / Speed break point for high current limit PIN 85
Note. 3)CURRENT LIMIT(%) set in the C ALIBRATION menu will prevail. This is the normal current limit
setting. How ever the profile calculation starts or ends at 150%.
6.8.4.3 I DYN A MIC PROFILE / Speed break point for low current limit PIN 86
6.8.4.4 I DYN A MIC PROFILE / Profile current for lo w current limit PIN 87
6.8.5 CURRENT C ON TROL / Dual current clamps enable PIN 88
If 88)DU AL I CLA MP ENBL is disabled then the clamps produce symmetric + ve and –ve current limits in
conjunction with 81)CUR CLA MP SC ALER. The default control terminal is T6. If 88)DU AL I CLA MP ENBL
(default terminal T21) is enabled then the upper input is default T6 and the lower input is default T5. Each
clamp can work in each polarity provided the upper is algebraically above the lo wer
How ever: If the upper clamp is set negative and the lo wer clamp set positive than the result is 0.00 %.
If the lo wer clamp is more positive than the upper clamp in the positive region the upper clamp behaves as a
current demand.
If the upper clamp is more negative than the lo wer clamp in the negative region the lo wer clamp behaves as
a current demand.
I DYN A MIC PROFILE 4
85)SPD BRPNT A T HI I
85)SPD BRPNT A T HI I
75.00%
PARA METER RANGE DEF AULT PIN
SPD BRPN T A T HI I 0.00 to 105.00 % 75.00 % 85
Sets the speed break point for
150% CURRENT LIMIT.
I DYN A MIC PROFILE 4
86)SPD BRPNT A T LO I
86)SPD BRPNT A T LO I
100.00 %
PARA METER RANGE DEF AULT PIN
SPD BRPN T A T LO I 0.00 to 105.00 % 100.00 % 86
Sets the speed break point for
87)C UR LIMIT A T LO I
I DYN A MIC PROFILE 4
87)C UR LIMIT A T LO I
87)C UR LIMIT A T LO I
100.00 %
PARA METER RANGE DEF AULT PIN
CUR LIMIT A T LO I 0.00 to 150.00 % 100.00% 87
Sets the current limit prevailing
at 86)SPEED BRPN T A T LO I
CURRENT C ON TROL 3
88)DU AL I CLA MP ENBL
88)DU AL I CLA MP ENBL
DISABLED
PARA METER RANGE DEF AULT PIN
DUAL I CLA MP ENBL ENABLED OR DIS ABLED DISABLED 88
Enables the upper and lo wer
dual clamps to be independant